Main
Device short name
XY2C
reset
By pull button
Complementary
compatibility code
XY2CJ
Product certifications
UL category NISD emergency stop devices, CSA, CCC, EAC
Product or component type
Latching emergency stop rope pull switch
Connections - terminals
Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
marking
CE
Housing colour
Red RAL 3000
contact operation
Slow-break
Contacts type and composition
1 NC + 1 NO
safety reliability data
B10d = 500000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Local signalling
Color indicator
head material
PA (polyamide)
cover material
Galvanised steel
Positive opening
With conforming to IEC 60947-5-1
trigger cable anchor point
RH or LH side
Shock resistance
50 gn 11 ms conforming to IEC 60068-2-27
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3, 25 MOhm conforming to NF C 93-050 method A
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Terminals description iso n°1
(21-22)NC(13-14)NO
Environment
ip degree of protection
IP66 conforming to IEC 60529, IP67 conforming to IEC 60529
Range of product
Telemecanique Emergency stop rope pull switches XY2C
overvoltage category
Class I conforming to IEC 61140
standards
CSA C22.2 No 14machinery directive 2006/42/ECIEC 60947-5-5UL 508IEC 60947-5-1IEC 60204-1work equipment directive 2009/104/ECISO 13850
vibration resistance
10 gn (f= 10-150 Hz) conforming to IEC 60068-2-6
protective treatment
TC