Main
Device short name
XY2CED
reset
By booted push-button
Complementary
compatibility code
XY2CED
Product certifications
UL category NISD emergency stop devices, CSA, CCC, EAC
Product or component type
Dual emergency stop rope pull switch
Connections - terminals
Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
marking
CE
Bellow material
Silicone
Housing colour
Red RAL 3000
contact operation
Slow-break
Contacts type and composition
2 x (1 NC + 1 NO)
safety reliability data
B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Local signalling
With pilot light, yellow, 24...130 V
cover material
Stainless steel
Positive opening
With conforming to IEC 60947-5-1
trigger cable anchor point
RH and LH sides
Shock resistance
50 gn 11 ms conforming to IEC 60068-2-27
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Terminals description iso n°1
(21-22)NC(13-14)NO
Environment
ip degree of protection
IP66 conforming to IEC 60529
Range of product
Telemecanique Emergency stop rope pull switches XY2C
overvoltage category
Class I conforming to IEC 61140
standards
CSA C22.2 No 14machinery directive 2006/42/ECIEC 60947-5-5UL 508IEC 60947-5-1IEC 60204-1work equipment directive 2009/104/ECISO 13850
vibration resistance
10 gn (f= 10-300 Hz) conforming to IEC 60068-2-6
protective treatment
TC