Main
Body type
Fixed
Series name
General purpose
sensor name
XS2
Complementary
Product certifications
CSAULE2
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
<= 10 mA no-load
detection face
Frontal
marking
CE
Device application
Mobile equipment
Discrete output function
1 NO
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Non flush mountable
Differential travel
1...15 % of Sr
Material
Metal
switching frequency
<= 1000 Hz
Discrete output type
NPN
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Front material
PPS
thread type
M18 x 1
electrical connection
Male connector M12, 4 pins
output circuit type
DC
Sensing range
> 15...40 mm
Sensor type
Inductive proximity sensor
Voltage drop
<2 V (closed)
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M18
Status led
Output state: 1 LED (yellow)
Wiring technique
3-wire
Size
51 mm
Type of output signal
Discrete
Environment
ip degree of protection
IP65 conforming to IEC 60529, IP67 conforming to DIN 40050, IP69K
Range of product
Telemecanique Inductive proximity sensors XS
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6