Main
Body type
Fixed
Device short name
XCKM
Series name
Standard format
head type
Plunger head
Complementary
Product certifications
CSACCCUL
Product or component type
Limit switch
cable entry
3 entries tapped for Pg 11 cable gland
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Electrical shock protection class
Class I conforming to IEC 61140, class I conforming to NF C 20-030
Fixing mode
By the body
body material
Zamak
Material
Metal
Type of operator
Spring return plunger metal
Ik degree of protection
IK05 conforming to IEC 62262
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix A, Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
repeat accuracy
0.05 mm on the tripping points with 1 million operating cycles
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Movement of operating head
Linear
Switch actuation
On end
Type of approach
Vertical approach, 1 direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Terminals description iso n°1
(21-22)NC(13-14)NO
Environment
ip degree of protection
IP66 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
standards
CSA C22.2 No 14UL 508IEC 60947-5-1IEC 60204-1
vibration resistance
25 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
protective treatment
TC