Main
Device short name
XY2CED
reset
By key-release push-button
Complementary
key number
421
Product certifications
INERIS 04ATEX0015IEC-Ex INE 16.0001X
Auxiliary contacts operation
Slow-break
Product or component type
Dual emergency stop rope pull switch
Connections - terminals
Screw clamp terminal, 1 x 0.5...2 x 1.5 mm², screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
marking
II2 D-Ex tb IIIC T85°C Db IP65
Housing colour
Red RAL 3000, red RAL 3000
Contacts type and composition
2 x (1 NC + 1 NO)
Electrical shock protection class
Class I conforming to EN/IEC 61140, class I conforming to EN/IEC 61140, class I conforming to NF C 20-030, class I conforming to NF C 20-030
safety reliability data
B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear
Local signalling
Without pilot light
Positive opening
With conforming to EN/IEC 60947-5-1 section 3, with conforming to EN/IEC 60947-5-1 section 3
trigger cable anchor point
RH and LH sides
Shock resistance
-
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3, 25 MOhm conforming to NF C 93-050 method A
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Environment
Directives
2014/34/EU - ATEX directive
ip degree of protection
IP65
Range of product
Telemecanique Emergency stop rope pull switches XY2C
Dust zone
Zone 21 - 22
standards
EN/IEC 60079-31EN/IEC 60079-0
vibration resistance
10 gn (f= 10-300 Hz) conforming to IEC 60068-2-6
protective treatment
TC