Main
Series name
General purpose single mode
sensor name
XUB
detection system
Polarised reflex
electronic sensor type
Photo-electric sensor
Complementary
[sn] nominal sensing distance
5-5 m polarised reflex need reflector XUZC50
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
< 20 mA no load
maximum voltage drop
<2 V (closed state)no-load
Output type
Discrete
Discrete output function
1 NO or 1 NC programmable
Enclosure material
PC/PBT
lens material
PMMA
Material
Metal
switching frequency
1000 Hz
Discrete output type
NPN
switching capacity in ma
<= 100 mA (overload and short-circuit protection)
electrical connection
Cable
Line of sight type
Axial
Shock resistance
30 gn (duration = 11 ms) for for every axis conforming to IEC 60068-2-27
Setting-up
Sensitivity by potentiometer
Sensor design
Cylindrical M18
Status led
1 LED (green) for supply on/stability, 1 LED (orange) for output state
Wiring technique
4 wires
Type of output signal
Discrete
Supply circuit type
DC
Environment
Emission
Red LED polarised reflex
ip degree of protection
IP67 conforming to IEC 60529, IP65 conforming to IEC 60529
Range of product
Telemecanique Photoelectric sensors XU
vibration resistance
7 gn, amplitude = +/- 1.5 mm (f = 10-55 Hz)for every axis conforming to IEC 60068-2-6