Main
Device short name
XMLR
Fluid connection type
G 1/4 (female) conforming to DIN 3852-Y
controlled fluid
Fresh water (0-80 °C), air (-20-80 °C), hydraulic oil (-20-80 °C), refrigeration fluid (-20-80 °C)
Pressure switch type of operation
Pressure transmitter with 1 switching output
pressure sensor type
Pressure transmitter
Complementary
Accuracy
<= 1 % of the measuring range
Product certifications
cULus
Product or component type
Electronic pressure sensors
[us] rated supply voltage
24 V DC SELV (voltage limits: 17-33 V)
Analogue output function
0...10 V
Current consumption
<= 50 mA
marking
CE
hysteresis
<= 0.2 % of the measuring range
Contacts type and composition
NO/NC programmable
Drift of the sensitivity
+/- 0,03 % of measuring range/°C
Drift of the zero point
+/- 0,01 % of measuring range/°C
Local signalling
1 LED (yellow) for light ON when switch is actuated
Display accuracy
<= 1 % of the measuring range
Discrete output type
Solid state PNP, NO/NC programmable
Display response time type
Fast 50 ms, normal 200 ms, slow 600 ms
measurement accuracy
<= 0.6 % of the measuring range
Operating position
Any position, but disposals can falsified the measurement in case of upside down mounting
Display type
4 digits 7 segments
repeat accuracy
<= 0.2 % of the measuring range
Front material
Polyester
Housing material
316L stainless steelpolyacrylamide
Materials in contact with fluid
316L stainless steelceramicfluorocarbon FKM (Viton)
Time delay range
0...50 s in steps of 1 second
electrical connection
Male connector M12, 4 pins
linearity error
<= 0.5 % of the measuring range
Voltage drop
2 VOLT
Shock resistance
50 gn conforming to IEC 60068-2-27
Response time on output
<= 10 ms for analog output, <= 5 ms for discrete output
Scale type
Fixed differential
Type of output signal
Analogue + discrete
Protection type
Overload protectionshort-circuit protectionovervoltage protectionreverse polarity
Environment
ip degree of protection
IP65 conforming to IEC 60529, IP67 conforming to IEC 60529
Range of product
Telemecanique Pressure sensors XM
electromagnetic compatibility
Susceptibility to electromagnetic fields: 10 V/m 80...2000 MHz conforming to IEC 61000-4-3, immunity to conducted RF disturbances: 10 V 0.15...80 MHz conforming to IEC 61000-4-6, surge immunity test: 1 kV conforming to IEC 61000-4-5, electrical fast transient/burst immunity test: 2 kV conforming to IEC 61000-4-4, electrostatic discharge immunity test: 8 kV air, 4 kV contact conforming to IEC 61000-4-2
standards
UL 61010-1IEC 61326-2-3
vibration resistance
20 gn (f= 10-2000 Hz) conforming to IEC 60068-2-6