Main
Body type
Fixed
Device short name
XCKD
Series name
Standard format
head type
Rotary head
Complementary
Product certifications
CSACCCUL
Product or component type
Limit switch
cable entry
1 entry tapped for Pg 11 cable gland
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
2 NC + 1 NO
Electrical shock protection class
Class I conforming to IEC 61140, class I conforming to NF C 20-030
Fixing mode
By the body
body material
Zamak
Material
Metal
Type of operator
Spring return roller lever thermoplastic
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 10 A conforming to IEC 60947-5-1, B300, AC-15 (Ue = 240 V), Ie = 10 A conforming to IEC 60947-5-1 appendix A, R300, DC-13 (Ue = 250 V) conforming to IEC 60947-5-1, R300, DC-13 (Ue = 250 V) conforming to IEC 60947-5-1 appendix A
head material
Zamak
repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 0.75 mm²
Movement of operating head
Rotary
Switch actuation
By 30° cam
Type of approach
Lateral approach, 2 directions
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Sensor design
Compact
Terminals description iso n°1
(21-22)NC(13-14)NO
Environment
ip degree of protection
IP66 conforming to IEC 60529, IP67 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
Dust zone
Zone 21 - 22
standards
CSA C22.2 No 14UL 508IEC 60947-5-1IEC 60204-1
vibration resistance
25 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
protective treatment
TC