Main
Associated head
ZCE24
ZCEH2
ZCE21
ZCE02
ZCE65
ZCE27
ZCE01
ZCE64
ZCE11
ZCE07
ZCE14
ZCE05
ZCE08
ZCEH0
ZCE62
ZCE28
ZCE67
ZCE10
ZCE29
ZCE06
ZCE66
ZCE13
ZCE63
Body type
Fixed
design
Compact
Device short name
Z CT
[ui] rated insulation voltage
300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Series name
Standard compact
Complementary
product compatibility
XCKT
Handle front plate colour
51 mm
Product or component type
Limit switch body
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
2 entries tapped for Pg 11 cable gland, cable outer diameter: 4…8 mm
Contacts insulation form
Zb
Contacts material
Silver plated contacts
contact operation
Slow-break, make before break
Contacts type and composition
1 NC + 1 NO
body material
Plastic
width (w)
58 mm
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.13 kg
depth
30 mm
electrical durability
5000000 cycles, DC-13 120 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 13 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 9 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Minimum actuation speed
6 m/s
Poles description
2
Short-circuit protection
10 A cartridge fuse, type gG
Environment
Ambient air temp for storage/transportation
-40…70 °C
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C