Main
Associated head
ZCE29
ZCE02
ZCE62
ZCEH2
ZCE01
ZCE07
ZCE08
ZCE24
ZCE10
ZCE21
ZCEH0
ZCE67
ZCE66
ZCE64
ZCE06
ZCE14
ZCE05
ZCE11
ZCE28
ZCE09
ZCE65
ZCE27
ZCE13
ZCE63
Body type
Fixed
design
Compact
Device short name
ZCP
[ui] rated insulation voltage
400 V (pollution degree 3) conforming to IEC 60947-1
Series name
Standard compact
Complementary
product compatibility
XCKP
Handle front plate colour
65 mm
Product or component type
Limit switch body
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Contacts insulation form
Zb
Contacts material
Silver plated contacts
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
body material
Plastic
width (w)
31 mm
contact code designation
B150, AC-15 (Ue = 120 V), Ie = 3 A, Ithe = 5 A conforming to EN/IEC 60947-5-1 appendix A
Q150, DC-13 (Ue = 125 V), Ie = 0.55 A conforming to EN/IEC 60947-5-1
Net weight
0.07 kg
depth
30 mm
electrical durability
5000000 cycles, DC-13 120 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 13 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 9 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Positive opening
With
electrical connection
DEUTSCH connector DT04-4P, 4 pins
Minimum actuation speed
0.01 m/s
Short-circuit protection
10 A cartridge fuse, type gG
Environment
Ambient air temp for storage/transportation
-40…70 °C
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C