All categories
Compare Cart

ZCMD81L1 - Limit switch body, Limit switches XC Standard, ZCMD, 2NC+2 NO, gold, snap action, connection, 1 m - Schneider Electric

Expected in 2-4 weeks
ZCMD81L1 - Limit switch body, Limit switches XC Standard, ZCMD, 2NC+2 NO, gold, snap action, connection, 1 m - Schneider Electric - Limit switch body, Limit switches XC Standard, ZCMD, 2NC+2 NO, gold, snap action, connection, 1 m - Schneider Electric - 0
ZCMD81L1 - Limit switch body, Limit switches XC Standard, ZCMD, 2NC+2 NO, gold, snap action, connection, 1 m - Schneider Electric
56,70 €
56,70 € incl. VAT
Text About:
Limit switch body, Limit switches XC Standard, ZCMD, 2NC+2 NO, gold, snap action, connection, 1 m - Schneider Electric
56,70 €
SPECIFICATIONS
Main
Associated head ZCEG1
ZCE14
ZCE64
ZCE65
ZCE11
ZCE09
ZCE28
ZCE27
ZCE66
ZCE08
ZCE21
ZCE07
ZCE24
ZCE62
ZCEF0
ZCE06
ZCE67
ZCE10
ZCE29
ZCEF2
ZCE13
ZCE01
ZCE02
ZCE63
Body type Fixed
design Miniature
Device short name ZCMD
cable length 1 m
[ui] rated insulation voltage 300 V (pollution degree 3) conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V (pollution degree 3) conforming to CSA C22.2 No 14
Series name Standard format
Complementary
product compatibility XCMD
cable composition 9 x 0.34 mm²
Handle front plate colour 50 mm
Product or component type Limit switch body
[uimp] rated impulse withstand voltage 4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Contacts insulation form Zb
Contacts material Gold plated contacts
contact operation Snap action
Contacts type and composition 2 NC + 2 NO
body material Zamak
width (w) 30 mm
Net weight 0.16 kg
depth 16 mm
electrical durability 5000000 cycles, DC-13 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Positive opening Without
electrical connection Fixed cable
Maximum resistance across terminals 25 mOhm conforming to IEC 60255-7 category 3
Minimum actuation speed 0.01 m/min
Poles description 4
Short-circuit protection 6 A cartridge fuse, type gG
Wire insulation material PvR
Environment
Ambient air temp for storage/transportation -40…70 °C
Range of product Telemecanique Limit switches XC Standard
Recently viewed
56,70 €
56,70 € incl. VAT
Expected in 2-4 weeks