Main
Associated head
ZCE02
ZCEH2
ZCE62
ZCE10
ZCE08
ZCE66
ZCE65
ZCE27
ZCE28
ZCE01
ZCE05
ZCE11
ZCE64
ZCE14
ZCE07
ZCE67
ZCE13
ZCE63
ZCE29
ZCE21
ZCE06
ZCEH0
ZCE24
Body type
Fixed
design
Compact
Device short name
ZCD
[ui] rated insulation voltage
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
400 V (pollution degree 3) conforming to IEC 60947-1
Series name
Standard compact
Complementary
product compatibility
XCKD
Handle front plate colour
65 mm
Product or component type
Limit switch body
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Associated connection component
ZCDEP16
ZCDEP20
ZCDEG11
ZCDEG13
ZCDEF12
ZCDEN12
Contacts insulation form
Zb
Contacts material
Silver plated contacts
contact operation
Slow-break, break before make
Contacts type and composition
2 NC + 1 NO
body material
Zamak
width (w)
31 mm
contact code designation
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
C300, AC-15 (Ue = 240 V), Ie = 0.75 A conforming to EN/IEC 60947-5-1 appendix A
depth
30 mm
electrical durability
5000000 cycles, DC-13 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 0.75 mm²
Minimum actuation speed
6 m/s
Poles description
3
Short-circuit protection
6 A cartridge fuse, type gG
Environment
Ambient air temp for storage/transportation
-40…70 °C
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C