All categories
Compare Cart

ZC1AZ11 - Limit switch contact block, Limit switches XC Standard, 1C/O - Schneider Electric

Expected in 2-4 weeks
ZC1AZ11 - Limit switch contact block, Limit switches XC Standard, 1C/O - Schneider Electric - Limit switch contact block, Limit switches XC Standard, 1C/O - Schneider Electric - 0
ZC1AZ11 - Limit switch contact block, Limit switches XC Standard, 1C/O - Schneider Electric
18,60 €
18,60 € incl. VAT
Text About:
Limit switch contact block, Limit switches XC Standard, 1C/O - Schneider Electric
18,60 €
SPECIFICATIONS
Main
Device short name ZC1A
[ithe] thermal current under enclosure 10 A
[ui] rated insulation voltage 500 V AC conforming to IEC 60947-5-1
500 V AC conforming to NF C 20-040
600 V DC conforming to IEC 60947-5-1
600 V DC conforming to NF C 20-040
600 V AC conforming to CSA C22.2 No 14
600 V DC conforming to CSA C22.2 No 14
Series name Special format
Complementary
product compatibility XC1AC11.
Product or component type Limit switch contact block
Contacts insulation form Za
Contacts material Silver plated contacts
contact operation Slow-break
Contacts type and composition 1 C/O
electrical durability 1000000 cycles, AC-15 110 V, 900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15 230 V, 1900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15 48 V, 450 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13 110 V, 100 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13 230 V, 95 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13 48 V, 100 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 110 V, 350 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 230 V, 430 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 48 V, 170 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13 110 V, 40 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13 230 V, 33 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13 48 V, 35 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Positive opening Without
electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Maximum resistance across terminals 8 mOhm conforming to IEC 60255-7 category 3
Minimum actuation speed 6 m/min
Poles description 1
Short-circuit protection 10 A cartridge fuse, type gG
Environment
Range of product OsiSense XC
Recently viewed
18,60 €
18,60 € incl. VAT
Expected in 2-4 weeks