Main
service life
100000 h at rated voltage and 25 °C
[ui] rated insulation voltage
24 V (pollution degree 3) conforming to EN/IEC 60947-1
Complementary
electrical insulation class
Class II conforming to IEC 61140
compatibility code
XB4
XB5
Accessory / separate part designation
Emergency switching off mushroom head push-button
Cap/operator or lens colour
2 colours choice
Product certifications
UL listed
CSA
Handle front plate colour
60 mm
Label dimensions
Ø 60 mm
Product or component type
Illuminated unmarked legend ring
[us] rated supply voltage
24 V AC/DC at 50/60 Hz
Current consumption
18 mA
Bulb base
Integral LED
marking
unmarked on yellow background
Operator additional information
With illuminated ring
Material
Plastic
Sale per indivisible quantity
1
width (w)
9.3 mm
Signalling type
Steady
supply voltage limits
19.2…30 V DC
21.6…26.4 V AC
Ik degree of protection
IK05 conforming to EN 50102
Net weight
0.016 kg
Device presentation
Intermediate ring
Shape of signaling unit head
Round
Light source colour
White or red
Resistance to high pressure washer
7000000 Pa at 55 °C, distance : 0.1 m
light source
Protected LED
Resistance to electrostatic discharge
4 kV on contact (on metal parts) conforming to IEC 61000-4-2
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Shock resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27
Resistance to electromagnetic fields
10 V/m conforming to IEC 61000-4-3
Surge withstand
1 kV conforming to IEC 61000-4-5
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
Type 13 conforming to UL 50E
Type 12 conforming to UL 50E
Type 4 conforming to UL 50E
Type 4X conforming to UL 50E
Range of product
Harmony
ambient air temperature for operation
-40…70 °C
standards
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60947-5-4
UL 508
EN/IEC 60947-1
JIS C8201-5-1
JIS C8201-1
electromagnetic emission
Class B conforming to IEC 55011
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
25 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6
protective treatment
TH
resistance to fast transients
2 kV conforming to IEC 61000-4-4