Main
Antenna type
Omnidirectional
Device short name
XB5R
Emission class
5M00G7W
number of channels
16
Complementary
Acquisition time
2 ms
Antenna gain
0 dBi
Bandwidth
5 MHz
Product certifications
CCC
BT 2006/95/EC
CSA
UL
C-Tick
GOST
response time
< 2 ms
Product or component type
Wireless and batteryless transmitter
nema degree of protection
NEMA 4X for outdoor installation
bezel material
Plastic
Cad overall depth
38 mm
transmission frequency
2405 MHz
Cad overall height
144 mm
Emission power
3 mW
Fixing mode
By screw: 1.8…2.2 N.m
Cad overall width
56 mm
Max power consumption in w
1 mW
mechanical robustness
Free fall resistance 1000 mm conforming to EN/IEC 60068-2-32
Ik degree of protection
IK05 conforming to IEC 50102
Modulation technique
O-QPSK
Mounting mode
Between 2 ropes
Panel-mounted
Radio agreement
ANATEL
ARIB T66
FCC
ICASA
RSS
SRRC
Net weight
0.15 kg
Operating position
Any position
communication port protocol
Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4
mechanical durability
1000000 cycles
Maximum sensing distance
100 m in free field
25 m transmitter in a plastic box type XAL D and receiver in a metal enclosure
300 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna
Pulling force
45…1000 N
Shock resistance
25 gn (duration = 6 ms) for 6000 shocks conforming to IEC 60068-2-27
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Environment
Ambient air temp for storage/transportation
-40…70 °C
Directives
1999/5/EC - R&TTE directive
2004/108/EC - electromagnetic compatibility
ip degree of protection
IP66 (outdoor) conforming to IEC 60529
Range of product
Harmony XB5
ambient air temperature for operation
-25…70 °C
electromagnetic compatibility
Electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts))
Electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts))
Susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz)
Susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m)
Immunity for industrial environments
Radiated emission
standards
CSA C22.2 No 14
EN/IEC 60947-5-1
UL 508
EN/IEC 60947-1
relative humidity
95 % at -25…70 °C without condensation
vibration resistance
5 gn (f= 11…500 Hz) conforming to IEC 60068-2-6
+/- 10 mm (f= 2…11 Hz) conforming to IEC 60068-2-6