Main
Antenna type
Omnidirectional
Device short name
ZBRA
Emission class
5M00G7W
number of channels
1
[ui] rated insulation voltage
250 V conforming to IEC 60664-1
Complementary
Antenna gain
0 dBi
Bandwidth
5 MHz
Product certifications
CCC
BT 2006/95/EC
UL
GOST
CSA
CE
C-Tick
Product or component type
Wireless and batteryless range
tightening torque
0.6 N.m conforming to EN/IEC 60947-1
[uimp] rated impulse withstand voltage
4 kV
[us] rated supply voltage
24...240 V AC/DC 50/60 Hz - 10...10 %
Colour of base of enclosure
Black (RAL 9011)
Electrical shock protection class
Class II conforming to IEC 61140
Emission power
3 mW
Material
Polycarbonate
Colour of cover
Transparent
Control station application
Transceiver (emission and reception)
Max power consumption in w
1 mW
Ik degree of protection
IK03 conforming to EN 50102
Modulation technique
O-QPSK
Radio agreement
RSS
SRRC
ANATEL, type III conforming to ETSI EN 301 489-3
ARIB T66, class 2 conforming to ETSI EN 301 489-3
FCC, category 2 conforming to ETSI EN 300 440-1
ICASA, category 1 conforming to ETSI EN 300 440-1
Net weight
0.2 kg
Operating position
Vertical
communication port protocol
Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4
frequency
2405 MHz for transmitter
2405 MHz for receiver
Maximum sensing distance
300 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna
Housing material
Self-extinguishing plastic
Pollution degree
3 conforming to IEC 60664-1
electrical connection
2 conductors cable 0.34 mm² - flexible - 5 m conforming to EN/IEC 60947-1
maximum power consumption in w
4 W AC/DC
Product destination
Wireless Schneider Electric ecosystem devices
Shock resistance
25 gn (duration = 6 ms) for 6000 shocks conforming to IEC 60068-2-27
15 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Rated short-duration power frequency withstand voltage
4 kV 50 Hz conforming to EN/IEC 60947-5-1
Status led
1 LED green for power ON
1 LED green for emission signal
Short-circuit protection
0.4 A fuse type fast blow
Environment
Ambient air temp for storage/transportation
-40…70 °C
Directives
1999/5/EC - R&TTE directive
2004/108/EC - electromagnetic compatibility
ip degree of protection
IP65 conforming to IEC 60529 55 °C 0.1 m
Range of product
Harmony XB5R
electromagnetic compatibility
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Conducted and radiated emissions class B conforming to CISPR 22
Electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 2 kV conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6
Immunity to microbreaks and voltage drops conforming to IEC 61000-4-11
Radiated emission conforming to ETSI EN 300 440-1
Conducted emission conforming to EN 300-489-1
Conducted emission conforming to ETSI EN 300 489-3
Radiated emission conforming to ETSI EN 300 440-2
overvoltage category
III conforming to IEC 60664-1
relative humidity
90 % at -20…55 °C, without condensation conforming to ETSI EN 300 440-1
vibration resistance
+/-0.5 mm (f= 10…55 Hz) conforming to IEC 60068-2-6
6 gn (f= 55…150 Hz) conforming to IEC 60068-2-6
insulation resistance
> 500 MOhm at 500 V DC conforming to NF C 20030