Main
Device short name
ZBE
[ui] rated insulation voltage
415 V
contact block type
Single
Complementary
[ie] rated operational current
1.9 A at 380 V, AC, A600 conforming to EN/IEC 60947-5-1
3 A at 240 V, AC, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC, A600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC, Q300 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC, Q300 conforming to EN/IEC 60947-5-1
2.87 A at 24 V, DC, Q300 conforming to EN/IEC 60947-5-1
[ith] conventional thermal current
10 A conforming to EN/IEC 60947-5-1
Product certifications
cULus
Product or component type
Contact block
tightening torque
0.8…1.2 N.m conforming to EN 60947-1
Connections - terminals
Screw clamp terminals, 2 x 1.5 mm² without cable end
Screw clamp terminals, 1 x 2.5 mm² with cable end
marking
Ex db eb IIC Gb
Cad overall depth
42.4 mm
Cad overall height
10 mm
contact operation
Standard
Contacts type and composition
1 NC
Operating travel
1.688 mm (engagement point)
3.271 mm (changing state point)
4.424 mm (total travel)
Cad overall width
38 mm
Sale per indivisible quantity
1
Contacts usage
Gas protected contact
Mounting of block
Front mounting
Net weight
0.019 kg
mechanical durability
1000000 cycles
Positive opening
With
Operating force
2.873 N
Environment
Ambient air temp for storage/transportation
-50…70 °C
Range of product
Harmony XB4
ambient air temperature for operation
-50…75 °C
Environmental characteristics
Hazardous location class I division 2
standards
UL 60079-31
UL 60079-0
UL 60079-1
ANSI/ISA 12.12.01
EN/IEC 60079-0
EN/IEC 60079-31
CSA C22.2 No 213
EN/IEC 60079-1
EN/IEC 60079-7
protective treatment
TH