Main
Device short name
ZB5
head type
Built-in-flush
Complementary
electrical composition code
C1 for <9 contacts using single blocks in front mounting
C2 for <9 contacts using single and double blocks in front mounting
C11 for <3 contacts using single blocks in front mounting
C15 for <1 contacts using single blocks in front mounting
SF1 for <3 contacts using single blocks in front mounting
product compatibility
ZBYF...
ZBZF32
ZBZF33
ZB5AZ
Product certifications
BV
LROS (Lloyds register of shipping)
DNV
GL
UL listed
CSA
mounting diameter
30.5 mm
Product or component type
Head for non-illuminated push-button
bezel material
Dark grey plastic
Cad overall depth
30 mm
Operator additional information
With set of 6 color cap
Cad overall height
37 mm
Cad overall width
37 mm
Sale per indivisible quantity
1
Type of operator
spring return
Ik degree of protection
IK03 conforming to IEC 50102
Net weight
0.03 kg
mechanical durability
10000000 cycles
Shape of signaling unit head
Round
Resistance to high pressure washer
7000000 Pa at 55 °C, distance : 0.1 m
Operator profile
6 colors choice flush, unmarked
Shock resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
Type 13 conforming to UL 50 E
Type 12 conforming to UL 50 E
Type 4 conforming to UL 50 E
Type 4X conforming to UL 50 E
Range of product
Harmony XB5
ambient air temperature for operation
-40…70 °C
overvoltage category
Class II conforming to IEC 60536
standards
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60947-5-4
JIS C8201-5-1
EN/IEC 60947-1
UL 508
JIS C8201-1
ISO 21702
ISO 22196:2011
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
2 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6
protective treatment
TH