Main
Device short name
XY2CH
[ithe] thermal current under enclosure
6 A
[ui] rated insulation voltage
400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
reset
By booted push-button
Complementary
[ie] rated operational current
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A
Cable entry number
3 tapped entry for Pg 13.5 cable gland
compatibility code
XY2CH
number of cables
1
Product certifications
UL category NISD emergency stop devices
CCC
Product or component type
Latching emergency stop rope pull switch
tightening torque
0.8…1.2 N.m
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
Connections - terminals
Screw clamp terminal, 1 x 0.34...1 x 1 mm²
Screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
marking
CE
Housing colour
Blue
contact operation
Slow-break
Contacts type and composition
2 NC + 1 NO
distance between cable supports
5 m
safety reliability data
B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Local signalling
Without pilot light
Net weight
0.91 kg
cover material
Stainless steel
mechanical durability
800000 cycles
Positive opening
With conforming to EN/IEC 60947-5-1
Maximum resistance across terminals
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
trigger cable anchor point
RH or LH side
Shock resistance
50 gn 11 ms conforming to EN/IEC 60068-2-27
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Trigger cable maximum length
30 m
Short-circuit protection
6 A cartridge fuse type gG conforming to EN/IEC 60269
Terminals description iso n°1
(21-22)NC
(31-32)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Emergency stop rope pull switches XY2C
ambient air temperature for operation
-40…70 °C
Environmental characteristics
Corrosive
overvoltage category
Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030
standards
Work equipment directive 2009/104/EC
EN/ISO 13850
EN/IEC 60947-5-5
EN/IEC 60204-1
EN/IEC 60947-5-1
Machinery directive 2006/42/EC
vibration resistance
10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6
protective treatment
TC