All categories
Compare Cart

XY2CH13293H29 - Latching emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e XY2CH, 2NC+1 NO, pilot light 24 V, booted pushbutton - Schneider Electric

Expected in 2-4 weeks
XY2CH13293H29 - Latching emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e XY2CH, 2NC+1 NO, pilot light 24 V, booted pushbutton - Schneider Electric - Latching emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e XY2CH, 2NC+1 NO, pilot light 24 V, booted pushbutton - Schneider Electric - 0
XY2CH13293H29 - Latching emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e XY2CH, 2NC+1 NO, pilot light 24 V, booted pushbutton - Schneider Electric
267,89 € excl. VAT
326,82 € incl. VAT
Text About:
Latching emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e XY2CH, 2NC+1 NO, pilot light 24 V, booted pushbutton - Schneider Electric
326,82 €
SPECIFICATIONS
Main
Device short name XY2CH
[ithe] thermal current under enclosure 6 A
[ui] rated insulation voltage 400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
reset By booted push-button
Complementary
[ie] rated operational current 0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A
Cable entry number 3 tapped entry for ISO M20 cable gland
compatibility code XY2CH
number of cables 1
Product certifications UL category NISD emergency stop devices
Product or component type Latching emergency stop rope pull switch
tightening torque 0.8…1.2 N.m
[uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1
[us] rated supply voltage 24 V
Connections - terminals Screw clamp terminal, 1 x 0.34...1 x 1 mm²
Screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
Light block supply Direct
marking CE
Housing colour Red RAL 3000
contact operation Slow-break
Contacts type and composition 2 NC + 1 NO
distance between cable supports 5 m
safety reliability data B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
body material Zamak
Local signalling With pilot light, yellow, 24 V
Net weight 0.865 kg
cover material Stainless steel
mechanical durability 800000 cycles
Positive opening With conforming to EN/IEC 60947-5-1
Maximum resistance across terminals 25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
trigger cable anchor point RH or LH side
Shock resistance 50 gn 11 ms conforming to EN/IEC 60068-2-27
Safety level Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Trigger cable maximum length 30 m
Short-circuit protection 6 A cartridge fuse type gG conforming to EN/IEC 60269
Terminals description iso n°1 (13-14)NON
(21-22)NC
(31-32)NC
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP65 conforming to IEC 60529
Range of product Telemecanique Emergency stop rope pull switches XY2C
ambient air temperature for operation -25…70 °C
overvoltage category Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030
standards Machinery directive 2006/42/EC
EN/IEC 60947-5-5
EN/IEC 60947-5-1
EN/IEC 60204-1
Work equipment directive 2009/104/EC
EN/ISO 13850
vibration resistance 10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6