Main
Device short name
XY2CE
[ithe] thermal current under enclosure
10 A
[ui] rated insulation voltage
500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
reset
By key-release push-button
Complementary
key number
421
[ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
Cable entry number
3 plain hole for Pg 13.5 or ISO M20 cable gland
compatibility code
XY2CE
number of cables
1
Product certifications
UL category NISD emergency stop devices
CSA
CCC
Product or component type
Latching emergency stop rope pull switch
tightening torque
0.8…1.2 N.m
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
Connections - terminals
Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
marking
CE
Housing colour
Red RAL 3000
contact operation
Slow-break
Contacts type and composition
1 NC + 1 NO
distance between cable supports
5 m
safety reliability data
B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Local signalling
Without pilot light
Net weight
1.465 kg
cover material
Stainless steel
mechanical durability
60000 cycles
Positive opening
With conforming to EN/IEC 60947-5-1
Maximum resistance across terminals
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
trigger cable anchor point
LH side
Shock resistance
50 gn 11 ms conforming to EN/IEC 60068-2-27
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Trigger cable maximum length
70 m
Short-circuit protection
10 A cartridge fuse type gG conforming to EN/IEC 60269
Terminals description iso n°1
(21-22)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Emergency stop rope pull switches XY2C
ambient air temperature for operation
-25…70 °C
overvoltage category
Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030
standards
EN/ISO 13850
EN/IEC 60947-5-1
EN/IEC 60204-1
CSA C22.2 No 14
EN/IEC 60947-5-5
UL 508
Machinery directive 2006/42/EC
Work equipment directive 2009/104/EC
vibration resistance
10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6
protective treatment
TC