Main
[sd] sensing range
0.420…4 m
Series name
General purpose
sensor name
XXS
detection system
Diffuse
Complementary
[sa] assured operating distance
0.420…4 m (teach mode)
[sn] nominal sensing distance
4 m adjustable with remote teach push-button
4 m software with kit
Product certifications
cULus
E2
EAC
RCM
Ecolab
Handle front plate colour
30 mm
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Analogue output function
4...20 mA
Blind zone
420 mm
Current consumption
65 mA
marking
CE
Enclosure material
Nickel plated brass
transmission frequency
80 kHz
Material
Metal
width (w)
40 mm
Deviation angle from 90° of object to be detected
-10…10 °
function available
With synchronisation mode
Software configurable
supply voltage limits
10…30 V DC
Net weight
0.21 kg
Maximum delay first up
500 ms
Maximum delay recovery
400 ms
depth
119 mm
repeat accuracy
0.1 %
Front material
Epoxy
Rubber
Resin
electrical connection
Male connector M12 5 pins
Maximum switching capacity
250 Ohm with 12 V DC overload and short-circuit protection
850 Ohm with 24 V DC
Minimum size of detected object
Cylinder diameter 1 mm at 1.8 m
Sensor type
Ultrasonic sensor
Resistance to electrostatic discharge
8 kV conforming to IEC 61000-4-2
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Setting-up
Teach mode
Configurator software
Sensor design
Cylindrical M30
Resistance to electromagnetic fields
10 V/m level 3 conforming to IEC 61000-4-3
Status led
Output state: 1 LED (yellow)
Echo state: 1 LED (green)
Threaded length
74.7 mm
Wiring technique
5-wire
Type of output signal
Analogue
Environment
Ambient air temp for storage/transportation
-40…80 °C
ip degree of protection
IP65 conforming to IEC 60529
IP67
Range of product
Telemecanique Ultrasonic sensors XX
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-2
CSA C22.2 No 14
UL 508
vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10…55 Hz)
resistance to fast transients
2 kV conforming to IEC 61000-4-4