Main
[sd] sensing range
0.105…1 m
Series name
General purpose
sensor name
XXS
detection system
Diffuse
Complementary
[sa] assured operating distance
0.105…1 m (teach mode)
[sn] nominal sensing distance
1 m adjustable with remote teach push-button
1 m software with kit
maximum switching current
100 mA with overload and short-circuit protection
Product certifications
cULus
EAC
RCM
E2
Ecolab
Handle front plate colour
18 mm
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Blind zone
105 mm
Current consumption
30 mA
maximum voltage drop
2 V
marking
CE
Discrete output function
1 NO or 1 NC programmable
Enclosure material
PBT
transmission frequency
200 kHz
Material
Plastic
width (w)
18 mm
Deviation angle from 90° of object to be detected
-10…10 °
function available
With synchronisation mode
Software configurable
supply voltage limits
10…30 V DC
switching frequency
11 Hz
Net weight
0.033 kg
Discrete output type
PNP
Maximum delay first up
120 ms
Maximum delay recovery
45 ms
depth
64 mm
Maximum delay response
45 ms
repeat accuracy
0.1 %
Maximum differential travel
4 mm
Front material
Epoxy
Rubber
Resin
electrical connection
Male connector M12 5 pins
Minimum size of detected object
Cylinder diameter 1 mm at 600 mm
Sensor type
Ultrasonic sensor
Resistance to electrostatic discharge
8 kV level 4 conforming to IEC 61000-4-2
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Setting-up
Teach mode
Configurator software
Sensor design
Cylindrical M18
Resistance to electromagnetic fields
10 V/m level 3 conforming to IEC 61000-4-3
Status led
Output state: 1 LED (yellow)
Echo state: 1 LED (green)
Threaded length
45 mm
Wiring technique
5-wire
Type of output signal
Discrete
Environment
Ambient air temp for storage/transportation
-40…80 °C
ip degree of protection
IP65 conforming to IEC 60529
IP67
Range of product
Telemecanique Ultrasonic sensors XX
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-2
CSA C22.2 No 14
UL 508
vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10…55 Hz)
resistance to fast transients