[sd] sensing range
0…0.6 m
Series name
General purpose
sensor name
XXR
detection system
Thru beam (need a transmitter XXT18A3M12)
Complementary
[sa] assured operating distance
0…0.6 m
[sn] nominal sensing distance
0.6 m fixed
maximum switching current
100 mA with overload and short-circuit protection
Product certifications
UL
Handle front plate colour
18 mm
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
40 mA
maximum voltage drop
1 V
marking
CE
Discrete output function
2 NO
Enclosure material
ULTEM
Material
Plastic
width (w)
18 mm
supply voltage limits
10…28 V DC
switching frequency
<= 40 Hz
Net weight
0.033 kg
Discrete output type
PNP and NPN
Maximum delay first up
100 ms
Maximum delay recovery
10 ms
depth
65 mm
Maximum delay response
10 ms
Front material
Silicone
thread type
M18 x 1
electrical connection
Male connector M12 4 pins
Sensor type
Ultrasonic sensor receiver
Resistance to electrostatic discharge
8 kV level 4 conforming to IEC 61000-4-2
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M18
Resistance to electromagnetic fields
10 V/m level 3 conforming to IEC 61000-4-3
Threaded length
51 mm
Wiring technique
4-wire
Type of output signal
Discrete
Environment
Ambient air temp for storage/transportation
-40…80 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Ultrasonic sensors XX
ambient air temperature for operation
0…60 °C
standards
IEC 60947-5-2
vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10…55 Hz)
resistance to fast transients
1 kV level 3 conforming to IEC 61000-4-4