[sd] sensing range
0.1…1 m
Series name
General purpose
sensor name
XX9
detection system
Diffuse
Complementary
[sa] assured operating distance
0.1…1 m (teach mode)
[sn] nominal sensing distance
1 m adjustable with remote teach push-button
Product certifications
cCSAus
UL
[us] rated supply voltage
15...24 V DC with reverse polarity protection
Analogue output function
4...20 mA
Beam angle
7 °
Blind zone
0…100 mm
Current consumption
60 mA
marking
CE
Enclosure material
Valox
transmission frequency
180 kHz
Material
Plastic
Deviation angle from 90° of object to be detected
-5…5 °
supply voltage limits
10…28 V DC
Net weight
0.3 kg
Maximum delay first up
1200 ms
Maximum delay recovery
250 ms
Maximum delay response
250 ms
repeat accuracy
0.9 %
Front material
Epoxy
thread type
M30 x 1.5
electrical connection
Male connector M12 4 pins
Maximum switching capacity
350 Ohm overload and short-circuit protection
Minimum size of detected object
Cylinder diameter 50.8 mm at 1 m
Sensor type
Ultrasonic sensor
Resistance to electrostatic discharge
8 kV level 4 conforming to IEC 61000-4-2
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Setting-up
Slope selection using teach button
Sensor design
Flat form 80 x 80 x 34
Resistance to electromagnetic fields
10 V/m level 3 conforming to IEC 61000-4-3
Status led
Setting-up assistance: 1 LED (dual colour)
Supply on: 1 LED (green)
Output state: 1 LED (yellow)
Wiring technique
4-wire
Type of output signal
Analogue
Environment
Ambient air temp for storage/transportation
-40…80 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Ultrasonic sensors XX
ambient air temperature for operation
0…70 °C
standards
IEC 60947-5-2
vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10…55 Hz)
resistance to fast transients
1 kV level 3 conforming to IEC 61000-4-4