Main
[sd] sensing range
0.0064…0.102 m
Series name
General purpose
sensor name
XX5
detection system
Diffuse
Complementary
[sa] assured operating distance
0.0064…0.102 m
[sn] nominal sensing distance
0.1 m fixed
maximum switching current
100 mA with overload and short-circuit protection
Product certifications
UL
Handle front plate colour
12 mm
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Beam angle
10 °
Blind zone
0…6.4 mm
Current consumption
25 mA
maximum voltage drop
1 V
marking
CE
Discrete output function
1 NO
Enclosure material
ULTEM
transmission frequency
500 kHz
Material
Plastic
width (w)
12 mm
Deviation angle from 90° of object to be detected
-10…10 °
supply voltage limits
10…28 V DC
switching frequency
<= 125 Hz
Net weight
0.011 kg
Discrete output type
PNP
Maximum delay first up
20 ms
Maximum delay recovery
3 ms
depth
50 mm
Maximum delay response
3 ms
repeat accuracy
0.7 %
Maximum differential travel
0.7 mm
Front material
Epoxy
thread type
M12 x 1
electrical connection
Male connector M8 3 pins
Minimum size of detected object
Cylinder diameter 2.5 mm
Flat bar 1 mm wide
Sensor type
Ultrasonic sensor
Resistance to electrostatic discharge
8 kV level 4 conforming to IEC 61000-4-2
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M12
Resistance to electromagnetic fields
10 V/m level 3 conforming to IEC 61000-4-3
Status led
Supply on: 1 LED (green)
Output state: 1 LED (yellow)
Threaded length
38 mm
Wiring technique
3-wire
Type of output signal
Discrete
Environment
Ambient air temp for storage/transportation
-40…80 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Ultrasonic sensors XX
ambient air temperature for operation
-20…65 °C
standards
IEC 60947-5-2
vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10…55 Hz)
resistance to fast transients
1 kV level 3 conforming to IEC 61000-4-4