Main
Specific application of photoelectric detector
Cement and plaster application
Wood and paper industry
Washing gantry
Atmosphere with high level of dust, vapor, rain, smoke
Food and beverage industry
Series name
Application
sensor name
XUY
detection system
Thru beam
electronic sensor type
Photo-electric sensor
Complementary
Associated complete product
XUY92CG41E.
XUY92CG41R.
Handle front plate colour
80 mm
[us] rated supply voltage
230 V AC
Output type
Relay
Enclosure material
NORYL
Material
Plastic
output voltage
250 V
width (w)
35 mm
supply voltage limits
195.5…264.5 V AC
switching frequency
15 Hz
Maximum delay recovery
33 ms
depth
84 mm
Maximum delay response
33 ms
Power consumption in va
2.5 VA
Time delay range
0...10 s
electrical connection
Plug-in sub-base
Setting-up
Sensitivity adjustment with potentiometer
Sensor design
Cylindrical M12
Status led
Supply on: 1 LED (green)
Output: 1 LED (red)
Sensitivity adjustment: 1 LED (yellow)
Supply circuit type
AC
Environment
Ambient air temp for storage/transportation
-50…85 °C
ip degree of protection
IP20
Range of product
Telemecanique Photoelectric sensors XU
ambient air temperature for operation
-20…50 °C