Main
product specific application
Distance measurement on object
Series name
Application assembly
Application material handling
sensor name
XUK
detection system
Diffuse with background suppression
electronic sensor type
Photo-electric sensor
Complementary
[sn] nominal sensing distance
5 m diffuse distance sensor
Add on input
External teach
Product certifications
Ecolab
cULus
CE
Analogue output range
4...20 mA
Handle front plate colour
50 mm
[us] rated supply voltage
24 V DC with reverse polarity protection
Current consumption
<= 60 mA no-load
maximum voltage drop
<2 V
Output type
Analog
Discrete output function
1 NO or 1 NC programmable
Enclosure material
ABS/PC
lens material
PMMA
Material
Plastic
width (w)
23 mm
supply voltage limits
18…30 V DC
switching frequency
<= 500 Hz
Net weight
0.035 kg
Discrete output type
IOLINK
PNP or NPN
Maximum delay first up
300 ms
Maximum delay recovery
1.2 ms
switching capacity in ma
<= 100 mA (overload and short-circuit protection)
depth
50 mm
Maximum delay response
1.2 ms
Maximum sensing distance
5 m diffuse distance sensor
electrical connection
1 male connector M12, 5 pins
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
Setting-up
Using teach button or remote teaching
Sensor design
Compact 50 x 50
Status led
1 LED (yellow) for output state
1 LED (green/yellow) for supply on/output state
Wiring technique
5-wire
Type of output signal
Analogue + discrete
Environment
Ambient air temp for storage/transportation
-40…80 °C
Emission
Red laser diffuse distance sensor class 1 conforming to IEC 60825-1
ip degree of protection
IP67 conforming to IEC 60529
IP69K conforming to IEC 60529
IP69K conforming to DIN 40050
Range of product
Telemecanique Photoelectric sensors XU
ambient air temperature for operation
-20…50 °C, UL certified
-40…60 °C
vibration resistance
7 gn, amplitude = +/- 1.5 mm (f = 10…55 Hz) conforming to IEC 60068-2-6