Main
product specific application
-
cable length
5 m
Series name
General purpose multimode
sensor name
XUK
detection system
Multimode
electronic sensor type
Photo-electric sensor
Complementary
[sn] nominal sensing distance
4 m polarised reflex need reflector XUZC50
30 m thru beam need a transmitter XUK0ARCTL5T
0.28 m diffuse with background suppression
0.8 m diffuse
Product certifications
CE
UL
CSA
Add on output
Without, <= 50 mA with overload and short-circuit protection
Handle front plate colour
50 mm
[us] rated supply voltage
24...240 V AC
24...240 V DC
maximum voltage drop
<1.5 V (closed state)
Output type
Relay
Discrete output function
1 NO or 1 NC programmable
Enclosure material
PBT
lens material
PMMA
Material
Plastic
width (w)
18 mm
supply voltage limits
20…264 V AC
20…264 V DC
switching frequency
<= 20 Hz
Net weight
0.175 kg
Maximum delay first up
300 ms
Maximum delay recovery
25 ms
switching capacity in ma
3 A (cos φ = 1 for 0.5 million cycles at 1 operating cycle per second at 250 V)
depth
50 mm
Maximum delay response
25 ms
electrical durability
500000 cycles, cos f = 1, operating rate <60 cyc/mn at 250 V
Maximum sensing distance
35 m thru beam
0.28 m diffuse with background suppression
1.2 m diffuse
5.7 m polarised reflex
Time delay range
0...10 s monostable, on-delay or off-delay (programmable) delay
electrical connection
Cable
maximum power consumption in w
3 W AC/DC
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
Setting-up
Self-teaching
Sensor design
Compact 50 x 50
Status led
1 LED (green) for supply
1 LED (red) for instability
1 LED (yellow) for output state
Wiring technique
5-wire
Type of output signal
Discrete
Supply circuit type
AC/DC
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…70 °C
Emission
Infrared diffuse
Infrared diffuse with background suppression
Infrared thru beam
Red polarised reflex
ip degree of protection
IP65 double insulation conforming to IEC 60529
Range of product
Telemecanique Photoelectric sensors XU
ambient air temperature for operation
-25…55 °C
vibration resistance
7 gn, amplitude = +/- 1.5 mm (f = 10…55 Hz) conforming to IEC 60068-2-6