Main
product specific application
-
cable length
2 m
Series name
Application assembly
sensor name
XUA
detection system
Thru beam
electronic sensor type
Photo-electric sensor
Complementary
[sn] nominal sensing distance
2 m thru beam need a transmitter XUAH0203
cable composition
3 x 0.14 mm²
length [l]
47 mm
Product certifications
CE
cULus
Add on output
Without
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
<= 10 mA no-load
maximum voltage drop
<1 V (closed state)
diameter
8 mm
cable outer diameter
3.5 mm
Output type
Solid state
Discrete output function
1 NO
Enclosure material
Nickel plated brass
lens material
PMMA
Material
Metal
supply voltage limits
10…30 V DC
switching frequency
<= 2000 Hz
Net weight
0.015 kg
Discrete output type
PNP
Maximum delay first up
20 ms
Maximum delay recovery
0.25 ms
switching capacity in ma
<= 100 mA (overload and short-circuit protection)
Maximum delay response
0.25 ms
Maximum sensing distance
4 m
electrical connection
Cable
Line of sight type
Axial
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
Setting-up
Without sensitivity adjustment
Sensor design
Cylindrical M8
Status led
1 LED (yellow) for output state
Wiring technique
3-wire
Type of output signal
Discrete
Supply circuit type
DC
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-30…70 °C
Emission
Infrared thru beam
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Photoelectric sensors XU
ambient air temperature for operation
-25…55 °C
vibration resistance
7 gn, amplitude = +/- 1 mm (f = 10…55 Hz) conforming to IEC 60068-2-6