Main
Device short name
XU2S
cable length
5 m
detection system
Transmitter-receiver system
Complementary
[sn] nominal sensing distance
8 m
cable composition
3 x 0.34 mm² for transmitter
4 x 0.34 mm² for receiver
Product or component type
Safety thru-beam pair photo-electric sensors
tightening torque
24 N.m fixing nut
[us] rated supply voltage
12...24 V DC 10...30 V reverse polarity protection
Current consumption
<= 35 mA no-load
maximum voltage drop
<1.5 V (closed)
cable outer diameter
5 mm
marking
CE
Output type
1 safety outputs OSSD PNP
safety reliability data
PFH = 5.5E-7 1/h conforming to IEC 61508 with muting function
PFH = 4.6E-7 1/h conforming to IEC 61508
Material
Nickel plated brass: case
PMMA (polymethyl methacrylate): lenses
function available
Built-in muting function
Light or dark programmable switching
switching frequency
500 Hz maximum
Net weight
0.485 kg
Maximum delay recovery
1 ms
switching capacity in ma
<= 100 mA (overload and short-circuit protection)
Maximum delay response
1 ms
electrical connection
Pre-cabled
Line of sight type
90° to case axis
Shock resistance
30 gn 3 axes : 3 times conforming to EN/IEC 60068-2-27
Safety level
Can reach PL = c associated with module XPSCM correctly wired conforming to EN/ISO 13849-1
Can reach category 2 associated with module XPSCM correctly wired conforming to EN/ISO 13849-1
Type 2 conforming to IEC 61496-1-2
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP67 conforming to EN/IEC 60529
Range of product
Telemecanique Safety light curtains XUSL
ambient air temperature for operation
-25…55 °C
standards
EN/IEC 60825-1
EN/IEC 61496-2
EN/IEC 61496-1
vibration resistance
7 gn (f= 10…55 Hz) conforming to EN/IEC 60068-2-6