Main
Body type
Fixed
cable length
10 m
Series name
Application
sensor name
XSA
Complementary
[sn] nominal sensing distance
10 mm
cable composition
3 x 0.34 mm²
Adjustable frequency range
6…150 cyc/mn
length [l]
81 mm
Product certifications
INERIS 04ATEX0022
IEC-Ex INE 17.0006
[us] rated supply voltage
12...48 V DC with reverse polarity protection
Current consumption
0...15 mA no-load
maximum voltage drop
<1.8 V (closed)
detection face
Frontal
marking
II2 D-Ex tb IIIC T90°C Db IP67
Device application
Rotation monitoring ATEX dust
Discrete output function
1 NC
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Flush mountable
Differential travel
3...15% of Fr
Material
Metal
supply voltage limits
10…58 V DC
switching frequency
<= 100 Hz
Net weight
0.3 kg
Discrete output type
PNP
switching capacity in ma
<= 200 mA with overload and short-circuit protection
repeat accuracy
3% of Sr
Front material
PPS
thread type
M30 x 1.5
electrical connection
Cable
output circuit type
DC
Operating zone
0…8 mm
Sensing range
8...15 mm
Sensor type
Inductive proximity sensor
Run-up delay at power-up
9 s standard
Sensor design
Cylindrical M30
Status led
Output state: 1 LED (red)
Threaded length
57 mm
Wiring technique
3-wire
Size
30 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Directives
2014/34/EU - ATEX directive
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-20…60 °C
Dust zone
Zone 21 - 22
Environmental characteristics
Hazardous location
standards
EN/IEC 60079-31
EN/IEC 60079-0