Main
Body type
Fixed
Series name
Application
sensor name
XS9
Complementary
[sn] nominal sensing distance
5 mm
cable composition
3 x 0.34 mm²
Product certifications
UL
CSA
Handle front plate colour
32 mm
[us] rated supply voltage
24 V DC
Current consumption
0...4 mA no-load
detection face
Frontal
marking
CE
Enclosure material
PBT
Detector flush mounting acceptance
Flush mountable
Material
Plastic
width (w)
15 mm
supply voltage limits
15…36 V DC
switching frequency
<= 2000 Hz
depth
8 mm
repeat accuracy
<= 3% of Sr
Front material
PBT
Maximum output current drift
10 %
output circuit type
DC
Operating zone
1…5 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Flat form 15 x 32 x 8
Status led
Without
Wiring technique
3-wire
Size
8 mm
Type of output signal
Analogue
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP68 conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6