Main
Body type
Fixed
Series name
Application
sensor name
XS9
Complementary
[sn] nominal sensing distance
40 mm
Product certifications
UL
Ecolab
CSA
Analogue output range
0...10 V
Handle front plate colour
80 mm
[us] rated supply voltage
24 V DC
Current consumption
0...4 mA no-load
detection face
Frontal
marking
CE
Device application
-
Enclosure material
PBT
Detector flush mounting acceptance
Flush mountable
Material
Plastic
width (w)
80 mm
supply voltage limits
15…36 V DC
switching frequency
<= 100 Hz
depth
26 mm
repeat accuracy
<= 3% of Sr
Front material
PBT
Maximum output current drift
10 %
electrical connection
Male connector M12, 4 pins
output circuit type
DC
linearity error
+/- 1 V
Operating zone
5…40 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Flat form 80 x 80 x 26
Status led
Without
Wiring technique
2-wire
Size
26 mm
Type of output signal
Analogue
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP67 double insulation conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance