Main
Body type
Fixed
cable length
0.15 m
Series name
General purpose
sensor name
XS8
Complementary
[sn] nominal sensing distance
10 mm flush mountable
15 mm non flush mountable
Product certifications
Ecolab
CSA
UL
Handle front plate colour
26 mm
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
<= 10 mA no-load
maximum residual current
1.5 mA open state
maximum voltage drop
<2 V (closed)
detection face
Frontal
marking
CE
Device application
-
Discrete output function
1 NC
Enclosure material
PBT
Detector flush mounting acceptance
Non flush mountable
Differential travel
1...15% of Sr
Material
Plastic
width (w)
26 mm
supply voltage limits
10…36 V DC
switching frequency
<= 2000 Hz
Net weight
0.04 kg
Discrete output type
PNP
Fine adjustment zone
5…10 mm flush mountable
5…15 mm non flush mountable
Maximum delay first up
10 ms
Maximum delay recovery
0.8 ms
switching capacity in ma
<= 100 mA DC with overload and short-circuit protection
depth
13 mm
Maximum delay response
0.3 ms
Front material
PBT
electrical connection
Remote male connector M12, 4 pins
output circuit type
DC
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Flat form 26 x 26 x 13
Wiring technique
3-wire
Size
13 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP67 double insulation conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6