All categories
Compare Cart

XS8C4A4PCP20EX - Inductive proximity sensors XS for hazardous area dust, 40x40x117, Sn40 mm, 12..48VDC, NO+NC, terminals - Schneider Electric

Expected in 2-4 weeks
XS8C4A4PCP20EX - Inductive proximity sensors XS for hazardous area dust, 40x40x117, Sn40 mm, 12..48VDC, NO+NC, terminals - Schneider Electric - Inductive proximity sensors XS for hazardous area dust, 40x40x117, Sn40 mm, 12..48VDC, NO+NC, terminals - Schneider Electric - 0
XS8C4A4PCP20EX - Inductive proximity sensors XS for hazardous area dust, 40x40x117, Sn40 mm, 12..48VDC, NO+NC, terminals - Schneider Electric
199,97 €
199,97 € incl. VAT
Text About:
Inductive proximity sensors XS for hazardous area dust, 40x40x117, Sn40 mm, 12..48VDC, NO+NC, terminals - Schneider Electric
199,97 €
SPECIFICATIONS
Main
Body type Fixed
Series name Application
sensor name XS8
Complementary
[sn] nominal sensing distance 40 mm
Cable entry number 1 tapped entry for M20 x 1.5 cable gland (included)
Product certifications INERIS 16ATEX0037X
IEC-Ex INE 16.0047X
Handle front plate colour 40 mm
[us] rated supply voltage 12...48 V DC with reverse polarity protection
Current consumption 0...15 mA no-load
maximum voltage drop <2 V (closed)
detection face 5 positions turret head
marking II2 D-Ex tb IIIC T85°C Db IP67
Device application ATEX dust
Discrete output function 1 NO + 1 NC
Enclosure material PBT
Detector flush mounting acceptance Non flush mountable
safety reliability data MTTFd = 1546 years
PFHd = 7.4E-8 1/h
SFF = 92 %
DC = 75 % with appropriate safety controller
Differential travel 3...15% of Sr
Material Plastic
width (w) 117 mm
supply voltage limits 10…58 V DC
switching frequency <= 200 Hz
Net weight 0.294 kg
Discrete output type PNP
Maximum delay first up 7.5 ms
Maximum delay recovery 2.5 ms
switching capacity in ma <= 200 mA with overload and short-circuit protection
depth 40 mm
Maximum delay response 1.4 ms
repeat accuracy <= 3% of Sr
Front material PBT
electrical connection Screw-clamp terminals, 4 x 1.5 mm²
output circuit type DC
Operating zone 0…16 mm
Sensing range > 15...40 mm
Sensor type Inductive proximity sensor
Shock resistance 50 gn for 11 ms conforming to EN 60068-2-27
Safety level SIL 2 conforming to EN/IEC 61508
PL = d conforming to EN/ISO 13849-1
SILCL 2 conforming to IEC 62061
Sensor design Form 40 x 40 x 117
Status led Supply on: 1 LED (green)
Output state: 1 LED (yellow)
Wiring technique 4-wire
Size 117 mm
Type of output signal Discrete
Environment
Ambient air temp for storage/transportation -25…70 °C
Directives 2014/34/EU - ATEX directive
ip degree of protection IP67 conforming to IEC 60529
IP65 conforming to IEC 60529
Range of product Telemecanique Inductive proximity sensors XS
ambient air temperature for operation -20…60 °C
Dust zone Zone 21 - 22
Environmental characteristics Hazardous location
standards EN/IEC 60079-0
EN/IEC 60079-31
vibration resistance 25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6
Recently viewed
199,97 €
199,97 € incl. VAT
Expected in 2-4 weeks