Complementary
[sn] nominal sensing distance
40 mm
Cable entry number
1 tapped entry for M20 x 1.5 cable gland (included)
Product certifications
INERIS 16ATEX0037X
IEC-Ex INE 16.0047X
Handle front plate colour
40 mm
[us] rated supply voltage
12...48 V DC with reverse polarity protection
Current consumption
0...15 mA no-load
maximum voltage drop
<2 V (closed)
detection face
5 positions turret head
marking
II2 D-Ex tb IIIC T85°C Db IP67
Device application
ATEX dust
Discrete output function
1 NO + 1 NC
Enclosure material
PBT
Detector flush mounting acceptance
Non flush mountable
safety reliability data
MTTFd = 1546 years
PFHd = 7.4E-8 1/h
SFF = 92 %
DC = 75 % with appropriate safety controller
Differential travel
3...15% of Sr
Material
Plastic
width (w)
117 mm
supply voltage limits
10…58 V DC
switching frequency
<= 200 Hz
Net weight
0.294 kg
Discrete output type
PNP
Maximum delay first up
7.5 ms
Maximum delay recovery
2.5 ms
switching capacity in ma
<= 200 mA with overload and short-circuit protection
depth
40 mm
Maximum delay response
1.4 ms
repeat accuracy
<= 3% of Sr
Front material
PBT
electrical connection
Screw-clamp terminals, 4 x 1.5 mm²
output circuit type
DC
Operating zone
0…16 mm
Sensing range
> 15...40 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to EN 60068-2-27
Safety level
SIL 2 conforming to EN/IEC 61508
PL = d conforming to EN/ISO 13849-1
SILCL 2 conforming to IEC 62061
Sensor design
Form 40 x 40 x 117
Status led
Supply on: 1 LED (green)
Output state: 1 LED (yellow)
Wiring technique
4-wire
Size
117 mm
Type of output signal
Discrete
Environment
Ambient air temp for storage/transportation
-25…70 °C
Directives
2014/34/EU - ATEX directive
ip degree of protection
IP67 conforming to IEC 60529
IP65 conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-20…60 °C
Dust zone
Zone 21 - 22
Environmental characteristics
Hazardous location
standards
EN/IEC 60079-0
EN/IEC 60079-31
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6