Main
Body type
Fixed
cable length
10 m
Series name
Application
sensor name
XS6
Complementary
[sn] nominal sensing distance
15 mm
cable composition
3 x 0.34 mm²
length [l]
62 mm
Product certifications
IEC-Ex INE 17.0006
INERIS 04ATEX0022
[us] rated supply voltage
12...48 V DC with reverse polarity protection
Current consumption
<= 10 mA no-load
maximum voltage drop
<2 V (closed state)
detection face
Frontal
marking
II2 D-Ex tb IIIC T90°C Db IP68
Device application
ATEX dust
Discrete output function
1 NC
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Flush mountable
Differential travel
1...15% of Sr
Material
Metal
supply voltage limits
10…58 V DC
switching frequency
<= 500 Hz
Discrete output type
PNP
Maximum delay first up
10 ms
Maximum delay recovery
1.4 ms
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Maximum delay response
0.6 ms
Front material
PPS
thread type
M30 x 1.5
electrical connection
Cable
output circuit type
DC
Operating zone
0…12 mm
Sensing range
> 8...15 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M30
Status led
Output state: 1 LED (yellow)
Threaded length
52 mm
Wiring technique
3-wire
Size
30 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Directives
2014/34/EU - ATEX directive
ip degree of protection
IP68 conforming to IEC 60529
IP69K
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-20…60 °C
Dust zone
Zone 21 - 22
Environmental characteristics
Hazardous location
standards
EN/IEC 60079-31
EN/IEC 60079-0
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6