Main
Body type
Fixed
cable length
2 m
Series name
General purpose
sensor name
XS4
Complementary
[sn] nominal sensing distance
15 mm
cable composition
4 x 0.22 mm²
length [l]
41 mm
Product certifications
CSA
UL
Handle front plate colour
30 mm
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
0...10 mA no-load
maximum voltage drop
<2 V (closed)
detection face
Frontal
marking
CE
Discrete output function
1 NO + 1 NC
Enclosure material
PPS
Detector flush mounting acceptance
Non flush mountable
Differential travel
1...15% of Sr
Material
Plastic
supply voltage limits
10…36 V DC
switching frequency
<= 1000 Hz
Net weight
0.16 kg
Discrete output type
PNP
Maximum delay first up
5 ms
Maximum delay recovery
0.7 ms
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Maximum delay response
0.3 ms
Front material
PPS
thread type
M30 x 1.5
electrical connection
Cable
output circuit type
DC
Operating zone
0…12 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M30
Status led
Output state: 1 LED (yellow)
Threaded length
33 mm
Wiring technique
4-wire
Size
41 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP68 double insulation conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6