Main
Body type
Fixed
cable length
10 m
Series name
General purpose
sensor name
XS4
Complementary
[sn] nominal sensing distance
8 mm
cable composition
2 x 0.34 mm²
length [l]
62 mm
Product certifications
UL
CSA
CCC
Handle front plate colour
18 mm
[us] rated supply voltage
24...240 V AC/DC 50/60 Hz
maximum residual current
0.6 mA open state
maximum voltage drop
<5.5 V (closed)
detection face
Frontal
marking
CE
Discrete output function
1 NO
Enclosure material
PPS
Detector flush mounting acceptance
Non flush mountable
Differential travel
1...15% of Sr
Material
Plastic
supply voltage limits
20…264 V AC/DC
switching frequency
<= 2000 Hz DC
<= 25 Hz AC
Net weight
0.42 kg
Maximum delay first up
40 ms
Maximum delay recovery
0.2 ms
switching capacity in ma
5...200 mA DC
5...300 mA AC
Maximum delay response
0.2 ms
Front material
PPS
thread type
M18 x 1
electrical connection
Cable
output circuit type
AC/DC
Operating zone
0…6.4 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M18
Status led
Output state: 1 LED (yellow)
Threaded length
52 mm
Wiring technique
2-wire
Size
62 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP68 double insulation conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6