Main
Body type
Fixed
cable length
10 m
Series name
General purpose
sensor name
XS2
Complementary
[sn] nominal sensing distance
4 mm
cable composition
4 x 0.22 mm²
length [l]
55 mm
Product certifications
UL
CSA
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
0...10 mA no-load
maximum voltage drop
<2.6 V (closed)
detection face
Frontal
marking
CE
Discrete output function
1 NO or 1 NC programmable
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Non flush mountable
Differential travel
1...15% of Sr
Material
Metal
supply voltage limits
10…36 V DC
switching frequency
<= 5000 Hz
Net weight
0.315 kg
0.075 kg
Discrete output type
PNP and NPN
Maximum delay first up
5 ms
Maximum delay recovery
0.1 ms
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Maximum delay response
0.1 ms
Front material
PPS
thread type
M12 x 1
electrical connection
Cable
output circuit type
DC
Operating zone
0…3.2 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M12
Status led
Output state: 1 LED (yellow)
Threaded length
42 mm
Wiring technique
4-wire
Size
55 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP68 double insulation conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6