Main
Body type
Fixed
Wiring configuration
2-wire
cable length
2 m
Series name
General purpose
sensor name
XS2
Complementary
cable composition
2 x 0.34 mm²
Product certifications
CCC
UL
CSA
[us] rated supply voltage
24...210 V DC
24...240 V AC 50/60 Hz
maximum residual current
1.5 mA open state
maximum voltage drop
<5.5 V (closed state)
detection face
Frontal
marking
CE
Device application
2-wire DC short-circuit protection
Discrete output function
1 NO
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Non flush mountable
Differential travel
1...15% of Sr
Material
Metal
switching frequency
<= 25 Hz AC
<= 4000 Hz DC
Maximum delay first up
70 ms
switching capacity in ma
5...200 mA AC/DC with overload and short-circuit protection
Front material
PPS
thread type
M8 x 1
electrical connection
Cable
output circuit type
AC/DC
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-7
Sensor design
Cylindrical M8
Status led
Output state: 1 LED (yellow)
Supply on: 1 LED (green)
Wiring technique
2-wire
Type of output signal
Discrete
Protection type
Short-circuit protection multi voltage
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6