Main
Body type
Fixed
service life
20 year(s)
cable length
2 m
Series name
General purpose
sensor name
XS1
Complementary
[sn] nominal sensing distance
10 mm
cable composition
4 x 0.22 mm²
length [l]
44 mm
Product certifications
CSA
UL
E2
TÜV
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
0...10 mA no-load
maximum voltage drop
<2 V (closed)
detection face
Frontal
marking
CE
Device application
Mobile equipment
Discrete output function
1 NO + 1 NC
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Flush mountable
safety reliability data
MTTFd = 1810 years
PFHd = 62.9E-9 1/h
SFF = 92 %
DC = 74 % with appropriate safety controller
Differential travel
1...15% of Sr
Material
Metal
supply voltage limits
9…36 V DC
switching frequency
<= 1000 Hz
Discrete output type
PNP
Maximum delay first up
5 ms
Maximum delay recovery
0.7 ms
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Maximum delay response
0.3 ms
Front material
PPS
thread type
M30 x 1.5
electrical connection
Cable
output circuit type
DC
Operating zone
0…8 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Safety level
SIL 2 conforming to EN/IEC 61508
PL = d conforming to EN/ISO 13849-1
SILCL 2 conforming to IEC 62061
Sensor design
Cylindrical M30
Status led
Output state: 1 LED (yellow)
Threaded length
32 mm
Wiring technique
4-wire
Size
44 mm
Type of output signal
Discrete
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP68 conforming to IEC 60529
IP65
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-40…70 °C
standards
IEC 62061
EN/ISO 13849-1
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6