Main
Body type
Fixed
cable length
2 m
Series name
General purpose
sensor name
XS1
Complementary
iso thread
M12 x 1
[sn] nominal sensing distance
2 mm
cable composition
3 x 0.14 mm²
length [l]
44 mm
Product certifications
CSA
UL
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
<= 10 mA no-load
maximum voltage drop
<2 V (closed)
detection face
Frontal
marking
CE
Discrete output function
1 NO
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Flush mountable
Differential travel
1...15% of Sr
Material
Metal
supply voltage limits
10…36 V DC
switching frequency
<= 2500 Hz
Net weight
0.07 kg
Discrete output type
PNP
Maximum delay first up
15 ms
Maximum delay recovery
0.15 ms
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Maximum delay response
0.1 ms
Front material
PBT
electrical connection
Cable
output circuit type
DC
Operating zone
0…1.6 mm
Sensor type
Inductive proximity sensor
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M12
Status led
Output state: 1 LED (yellow)
Threaded length
31 mm
Wiring technique
3-wire
Size
44 mm
Type of output signal
Discrete
Wire insulation material
PVC
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
ambient air temperature for operation
-25…70 °C
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10…55 Hz) conforming to IEC 60068-2-6