All categories
Compare Cart

XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric

Expected in 2-4 weeks
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 0
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 1
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 2
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 3
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 4
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 5
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric - 6
XPSUEP34AP - Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric
173,55 €
173,55 € incl. VAT
Text About:
Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, screw - Schneider Electric
173,55 €
SPECIFICATIONS
Main
Safety module application For extending number of safety contacts
Safety module name XPSUEP
[ui] rated insulation voltage 250 V (pollution degree 2) conforming to EN/IEC 60947-1
Complementary
[ie] rated operational current 5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
[ith] conventional thermal current 8 A
Product certifications TÜV
cULus
Handle front plate colour 100 mm
Product or component type Safety module
[uimp] rated impulse withstand voltage 4 kV overvoltage category II conforming to EN/IEC 60947-1
[us] rated supply voltage 48...240 V AC/DC - 10...10 %
Connections - terminals Removable screw terminal block, 0.2...2.5 mm² solid or flexible
Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Associated fuse rating 10 A gG for NO relay output circuit conforming to IEC 60947-1
4 A gG for NC relay output circuit conforming to IEC 60947-1
minimum output current 10 mA for relay output
Function of module Safety output extension
safety reliability data MTTFd > 30 years conforming to ISO 13849-1
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 1.61E-09 conforming to ISO 13849-1
HFT = 1 conforming to IEC 62061
PFHd = 1.61E-09 conforming to IEC 62061
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 1.61E-09 conforming to IEC 61508-1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
width (w) 22.5 mm
Electrical circuit type Addition to Preventa XPSU base module
Local signalling LED (green) for power ON
LED (red) for error
LED (yellow) for safety output status
maximum line resistance 60 Ohm
Net weight 0.200 kg
Maximum response time on input open 20 ms
Mounting support 35 mm symmetrical DIN rail
depth 120 mm
minimum output voltage 12 V for relay output
Power consumption in va 6.5 VA 240 V AC 50/60 Hz
Power consumption in w 2 W 48 V DC
Safety outputs 4 NO redundant
2 NC single
Input compatibility Normally closed circuit conforming to ISO 14119
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
Antivalent pair conforming to ISO 14119
OSSD pair conforming to IEC 61496-1-2
3-wire proximity sensors PNP
input protection type Internal, electronic
Safety inputs 0 extension bus 24 V DC 5 mA
Safety level Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Environment
Ambient air temp for storage/transportation -25…85 °C
ip degree of protection IP20 (terminals) conforming to EN/IEC 60529
IP40 (housing) conforming to EN/IEC 60529
IP54 (mounting area) conforming to EN/IEC 60529
Range of product Harmony Safety Automation
standards IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
relative humidity 5…95 % non-condensing