Complementary
Cable cross section
0.2…2.5 mm² - AWG 24...AWG 14 flexible cablewithout cable end
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel
0.2…2.5 mm² - AWG 24...AWG 14 solid cablewithout cable end
0.5…1 mm² - AWG 20...AWG 18 flexible cablewith cable end, with double bezel
Product certifications
RCM
cULus
TÜV
Handle front plate colour
99 mm
Product or component type
Safe mixed I/O expansion module
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 61800-5-1
[us] rated supply voltage
24 V - 20...20 % DC
Connections - terminals
1 spring clamp terminals, removable terminal block
2 spring clamp terminals, removable terminal block
Discrete output current
400 mA
100 mA
Function of module
Monitoring safety detection for discrete input
Monitoring safety dialogue for discrete input
Monitoring safety actuators for discrete output
safety reliability data
DC > 99 %
MTTFd < 100 years high
PFHd = 5.72E-9 1/h
width (w)
114.5 mm
Discrete input type
Isolated
number of outputs
4 test for line control
2 safety outputs OSSD for contactor/drive connection
2 configurable for diagnostic connection
Discrete input voltage
24 V DC
Local signalling
1 LED green with PWR marking for power ON
1 LED green with RUN marking for RUN (status)
1 LED red with E IN marking for internal error
1 LED red with E EX marking for external error
2 LEDs orange with ADDR marking for node address
8 LEDs yellow with IN marking for input status
2 LEDs green/red with OUT marking for output status
2 LEDs yellow with RST marking for restart signal
2 LEDs yellow with STATUS marking for output status
Net weight
0.25 kg
Discrete output type
PNP
Discrete output voltage
24 V DC
Integrated connection type
Backplane expansion bus
Mounting support
Omega 35 mm DIN rail conforming to EN 50022
depth
22.5 mm
power dissipation in w
3 W
Load type
Resistive load
Number of inputs
8 digital
2 digital for external device monitoring
Pollution degree
2
Power consumption in w
3 W
electrical connection
Spring terminal
Number of terminal blocks
6
Insulation
250 V AC between power supply and housing conforming to EN/IEC 61800-5-1
Output load
60 Ohm
Shock resistance
10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to EN/IEC 61496-1
Safety level
Can reach category 4 conforming to EN/ISO 13849-1
Can reach PL = e conforming to EN/ISO 13849-1
Can reach SIL 3 conforming to EN/IEC 61508
SILCL 3 conforming to IEC 62061
Environment
Ambient air temp for storage/transportation
-20…85 °C
ip degree of protection
IP20 (enclosure)
Range of product
Preventa Safety automation
ambient air temperature for operation
-10…55 °C
electromagnetic compatibility
Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
overvoltage category
II
standards
IEC 62061
EN/IEC 61508
EN/ISO 13849-1
EN/IEC 61800-5-1
quality labels
CE
relative humidity
10…95 %
vibration resistance