Complementary
Cable cross section
0.2…2.5 mm² - AWG 24...AWG 14 flexible cablewithout cable end
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel
0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel
0.2…2.5 mm² - AWG 24...AWG 14 solid cablewithout cable end
0.5…1 mm² - AWG 20...AWG 18 flexible cablewith cable end, with double bezel
Product certifications
cULus
RCM
TÜV
Handle front plate colour
99 mm
Product or component type
Safe output expansion module
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 61800-5-1
[us] rated supply voltage
24 V - 20...20 % DC
Connections - terminals
1 spring clamp terminals, removable terminal block
2 spring clamp terminals, removable terminal block
Discrete output current
400 mA
100 mA
Function of module
Monitoring safety actuators for discrete output
safety reliability data
DC > 99 %
MTTFd < 100 years high
PFHd = 3.16E-9 1/h
width (w)
114.5 mm
Discrete input type
Isolated
number of outputs
2 safety outputs OSSD for contactor/drive connection
2 configurable for diagnostic connection
Discrete input voltage
24 V DC
Local signalling
1 LED green with PWR marking for power ON
1 LED green with RUN marking for RUN (status)
1 LED red with E IN marking for internal error
1 LED red with E EX marking for external error
2 LEDs orange with ADDR marking for node address
2 LEDs green/red with OUT marking for output status
2 LEDs yellow with RST marking for restart signal
2 LEDs yellow with STATUS marking for output status
Net weight
0.23 kg
Discrete output type
PNP
Discrete output voltage
24 V DC
Integrated connection type
Backplane expansion bus
Mounting support
Omega 35 mm DIN rail conforming to EN 50022
depth
22.5 mm
power dissipation in w
3 W
Load type
Resistive load
Number of inputs
2 digital for external device monitoring
Pollution degree
2
Power consumption in w
3 W
electrical connection
Spring terminal
Number of terminal blocks
4
Insulation
250 V AC between power supply and housing conforming to EN/IEC 61800-5-1
Output load
60 Ohm
Shock resistance
10 gn (duration = 16 ms) for 1000 shocks on each axis conforming to EN/IEC 61496-1
Safety level
Can reach category 4 conforming to EN/ISO 13849-1
Can reach PL = e conforming to EN/ISO 13849-1
Can reach SIL 3 conforming to EN/IEC 61508
SILCL 3 conforming to IEC 62061
Environment
Ambient air temp for storage/transportation
-20…85 °C
ip degree of protection
IP20 (enclosure)
Range of product
Preventa Safety automation
ambient air temperature for operation
-10…55 °C
electromagnetic compatibility
Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
overvoltage category
II
standards
IEC 62061
EN/IEC 61508
EN/ISO 13849-1
EN/IEC 61800-5-1
quality labels
CE
relative humidity
10…95 %
vibration resistance
+/-0.35 mm (f= 10…55 Hz) conforming to EN/IEC 61496-1