Complementary
[ics] rated service breaking capacity
2 A at 24 V for static output circuit
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
[ith] conventional thermal current
16 A for relay output
6.5 A for static output circuit
Product certifications
TÜV
UL
CSA
response time
Configurable : 20 ms or 30 ms with software XPSMCWIN
data formats
1 start bit/8 data bits
1 stop bit even or odd
2 stop bits without parity
RTU (Remote Terminal Unit) mode
Handle front plate colour
151.5 mm
Product or component type
Configurable safety controller
[uimp] rated impulse withstand voltage
4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1
[us] rated supply voltage
24 V DC - 20...20 %
Associated fuse rating
16 A gL for power supply
4 A gL for relay output
6 A fast blow for relay output
minimum output current
10 mA for relay output
output thermal current
4 A for both outputs simultaneously
6 A for 1 output and 2 A for the other for relay output
Output type
2 relays, 2 NO contacts (4 NO total) circuit(s)
Solid state, 6 circuit(s), volt-free
Function of module
Dynamic monitoring of hydraulic valves on linear presses
Eccentric press
Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
Enabling switch monitoring, 2 or 3 contacts
Foot switch monitoring
Guard monitoring for injection presses and blowing machines
Guard monitoring with 1 or 2 limit switches
Hydraulic press
Magnetic switch monitoring
Monitoring safety stop at top dead centre on eccentric press
Muting function of light curtains
Position selector
Safety mat monitoring
Safety time delays
Shaft/chain breaking monitor
Zero speed detection
Light curtain monitoring category 4 conforming to EN/IEC 61496
Two-hand control category 3 conforming to EN 574/ISO 13851
width (w)
74 mm
Local signalling
30 LEDs
Exchange size
14 words
maximum line resistance
100 Ohm <2000 m
Net weight
0.82 kg
communication port protocol
Modbus with 1 RJ45 port(s), serial link, transmission rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
Mounting support
Mounting plate
depth
153 mm
minimum output voltage
17 V for relay output
Number of inputs
16
Power consumption in w
12 W
input protection type
External fuse 16 A
Parity
Even for Modbus
No for Modbus
Odd for Modbus
Synchronisation time between inputs
Depending on configuration selected
Method of access
Slave
Safety level
Can reach PL e/category 4 conforming to EN 954-1/EN/ISO 13849-1
Can reach SIL 3 conforming to IEC 61508
Supported modbus function
01: 8-bit output data/32-bit input data
02: 32-bit input data/8-bit output data
03: information and errors
number of addresses
1…247 for Modbus
Type of start
Configurable
Environment
Ambient air temp for storage/transportation
-25…85 °C
ip degree of protection
IP20 conforming to EN/IEC 60529
Range of product
Preventa Safety automation
ambient air temperature for operation
-10…55 °C
standards
EN 574/ISO 13851
EN 1760-1/ISO 13856-1
EN/IEC 61496-1
EN/IEC 60204-1
IEC 61508
EN/IEC 60947-5-1
EN 954-1/EN/ISO 13849-1