All categories
Compare Cart

XPSCM1144P - Module XPSCM singlebeam photoelectric sensors 24 V DC - Schneider Electric

Expected in 2-4 weeks
XPSCM1144P - Module XPSCM singlebeam photoelectric sensors 24 V DC - Schneider Electric - Module XPSCM singlebeam photoelectric sensors 24 V DC - Schneider Electric - 0
XPSCM1144P - Module XPSCM singlebeam photoelectric sensors 24 V DC - Schneider Electric
368,43 €
368,43 € incl. VAT
Text About:
Module XPSCM singlebeam photoelectric sensors 24 V DC - Schneider Electric
368,43 €
SPECIFICATIONS
Main
Safety module application For monitoring of single beam photo-electric sensor
Safety module name XPSCM
[ui] rated insulation voltage 300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2
300 V (pollution degree 2) conforming to EN/IEC 60947-5-1
Complementary
[ics] rated service breaking capacity 20 mA at 24 V for solid state output
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Product or component type Safety module
[uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2
4 kV overvoltage category III conforming to EN/IEC 60947-5-1
[us] rated supply voltage 24 V DC - 20...20 %
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid or flexible without cable end
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible without cable end
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Associated fuse rating 4 A gG for relay output conforming to DIN VDE 0660 part 200
4 A gG for relay output conforming to EN/IEC 60947-5-1
6 A fast blow for relay output conforming to DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1
minimum output current 10 mA for relay output
output thermal current 5.6 A per relay
11 A maximum
Output type Relay 2 NO (13-14, 23-24), volt-free
Function of module Built-in muting
input current 200 mA for muting function
safety reliability data MTTFd = 16.6 years conforming to EN/ISO 13849-1
DC = 95.5 % conforming to EN/ISO 13849-1
PFH = 3.12E-7 1/h conforming to EN/IEC 61508
PFHd = 3.12E-7 1/h conforming to EN/IEC 62061
Local signalling 1 LED, function electronic internal fuse status
1 LED, function restarting
1 LED, function safety outputs closed
1 LED, function safety outputs open
1 incandescent lamp, function muting power consumption: 4…6.5 W
maximum line resistance 10 Ohm for sensor power supply
Maximum response time on input open 25 ms
Maximum supply current for sensors 200 mA
minimum output voltage 17 V for relay output
Muting maximum duration 60 s (- 10...30 %)
Number of inputs 2 (terminal(s) MA, MB) for muting function
4 (terminal(s) Z1, Z2, Z3, Z4) for sensor
Power consumption in w 15 W
input voltage 24 V DC for sensor
24 V DC (terminal(s) U+, U-) for muting function
Sensor power supply U+, U-: 24 V DC
Input compatibility XC limit switch for muting function
XU2M18PP340... for muting function
XU2S18PP340... (infrared) for sensor
XU9M18PP340... for muting function
Synchronisation time between inputs 3 s (+/- 20 %) for the activation of the MA/MB muting signal
Safety level Can reach category 2 with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
Can reach SILCL 1 with the appropriate control system and correctly wired conforming to EN/IEC 62061
Can reach PL = c with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
Protection type Electronic internal fuse
Environment
Ambient air temp for storage/transportation -25…85 °C
ip degree of protection IP20 (terminals) conforming to IEC 60529
IP40 (enclosure) conforming to IEC 60529
Range of product Telemecanique Safety light curtains XUSL
ambient air temperature for operation -10…55 °C
Recently viewed
368,43 €
368,43 € incl. VAT
Expected in 2-4 weeks