Complementary
[ie] rated operational current
5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
[ith] conventional thermal current
12 A
Product certifications
TÜV
cULus
Handle front plate colour
100 mm
Product or component type
Safety module
[uimp] rated impulse withstand voltage
4 kV overvoltage category II conforming to EN/IEC 60947-1
[us] rated supply voltage
24 V AC - 15...10 %
24 V DC - 20...20 %
Connections - terminals
Removable spring terminal block, 0.2...2.5 mm² solid or flexible
Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Associated fuse rating
6 A gG for NO relay output circuit conforming to IEC 60947-1
minimum output current
20 mA for relay output
Function of module
Emergency stop button with 2 NC contacts
Guard monitoring with 1 or 2 limit switches
Light curtain monitoring
RFID switch
Monitoring of electro-sensitive protection equipment (ESPE)
safety reliability data
MTTFd > 30 years conforming to ISO 13849-1
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 0.98E-09 conforming to ISO 13849-1 for SS0
PFHd = 0.96E-09 conforming to ISO 13849-1 for SS1
HFT = 1 conforming to IEC 62061
PFHd = 0.98E-09 conforming to IEC 62061 for SS0
PFHd = 0.96E-09 conforming to IEC 62061 for SS1
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 0.98E-09 conforming to IEC 61508-1 for SS0
PFHd = 0.96E-09 conforming to IEC 61508-1 for SS1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
Control outputs
3 on/off configurable pulsed output
width (w)
22.5 mm
Electrical circuit type
NC pair
OSSD pair
Local signalling
LED green with power marking for power ON
LED red with error marking for error
LED yellow with state 1 marking for safety output instantaneous
LED yellow with state 2 marking for safety output delayed
LED yellow with start 1 marking for start
LED yellow with start 2 marking for start
LED yellow with S12 marking for safety input S12
LED yellow with S22 marking for safety input S22
Net weight
0.350 kg
Maximum response time on input open
20 ms
Mounting support
35 mm symmetrical DIN rail
depth
120 mm
minimum output voltage
24 V for relay output
Power consumption in va
5 VA 24 V AC 50/60 Hz
Power consumption in w
2 W 24 V DC
Time delay range
0...900 s off delay
Maximum wire resistance
500 Ohm
Safety outputs
2 NO immediate
1 NO configurable
Input compatibility
Normally closed circuit conforming to ISO 14119
Mechanical contact conforming to ISO 14119
OSSD pair conforming to IEC 61496-1-2
Normally closed circuit conforming to ISO 13850
3-wire proximity sensors PNP
input protection type
Internal, electronic
Synchronisation time between inputs
0.5 s
2 s
Safety inputs
2 positive safety input 24 V DC 5 mA
Safety level
Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Type of start
Automatic/manual/monitored
Environment
Ambient air temp for storage/transportation
-25…85 °C
ip degree of protection
IP20 (terminals) conforming to EN/IEC 60529
IP40 (housing) conforming to EN/IEC 60529
IP54 (mounting area) conforming to EN/IEC 60529
Range of product
Harmony Safety Automation
ambient air temperature for operation
-25…55 °C
standards
IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
relative humidity
5…95 % non-condensing