All categories
Compare Cart

XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric

Expected in 2-4 weeks
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 0
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 1
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 2
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 3
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 4
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 5
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric - 6
XPSBAC34AC - Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric
164,05 € excl. VAT
200,14 € incl. VAT
Text About:
Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC/DC , no inputs, spring - Schneider Electric
200,14 €
SPECIFICATIONS
Main
Safety module application For emergency stop and protective guard applications
Safety module name XPSBAC
[ui] rated insulation voltage 300 V (pollution degree 2) conforming to EN/IEC 60947-1
Complementary
[ie] rated operational current 5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
3 A AC-1 for normally closed relay contact
1 A AC-15 for normally closed relay contact
3 A DC-1 for normally closed relay contact
1 A DC-13 for normally closed relay contact
[ith] conventional thermal current 6 A
Product certifications TÜV
cULus
response time 60 ms at 48...240 V AC/DC
Handle front plate colour 100 mm
Product or component type Safety module
[uimp] rated impulse withstand voltage 4 kV overvoltage category II conforming to EN/IEC 60947-1
[us] rated supply voltage 48...240 V AC - 15...10 %
48...240 V DC - 20...20 %
Connections - terminals Removable spring terminal block, 0.2...2.5 mm² solid or flexible
Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Associated fuse rating 10 A gG for NO relay output circuit conforming to IEC 60947-1
minimum output current 10 mA for relay output
Function of module Emergency stop button with 2 NC contacts
Guard monitoring with 1 or 2 limit switches
safety reliability data MTTFd > 30 years conforming to ISO 13849-1 for normally open relay contact
Dcavg >= 99 % conforming to ISO 13849-1 for normally open relay contact
PFHd = 1.01E-09 conforming to ISO 13849-1 for normally open relay contact
HFT = 1 conforming to IEC 62061 for normally open relay contact
PFHd = 1.01E-09 conforming to IEC 62061 for normally open relay contact
SFF > 99% conforming to IEC 62061 for normally open relay contact
HFT = 1 conforming to IEC 61508-1 for normally open relay contact
PFHd = 1.01E-09 conforming to IEC 61508-1 for normally open relay contact
SFF > 99% conforming to IEC 61508-1 for normally open relay contact
Type = B conforming to IEC 61508-1 for normally open relay contact
MTTFd > 30 years conforming to ISO 13849-1 for normally closed relay contact
DC > 60 % conforming to ISO 13849-1 for normally closed relay contact
PFHd = 1.01E-09 conforming to ISO 13849-1 for normally closed relay contact
HFT=0 conforming to IEC 62061 for normally closed relay contact
PFHd = 1.01E-09 conforming to IEC 62061 for normally closed relay contact
SFF > 60% conforming to IEC 62061 for normally closed relay contact
HFT=0 conforming to IEC 61508-1 for normally closed relay contact
PFHd = 1.01E-09 conforming to IEC 61508-1 for normally closed relay contact
SFF > 60% conforming to IEC 61508-1 for normally closed relay contact
Type = B conforming to IEC 61508-1 for normally closed relay contact
width (w) 22.5 mm
Electrical circuit type NC pair
Local signalling LED green with power marking for power ON
LED red with error marking for error
LED yellow with state marking for status
LED yellow with start1 marking for start input
LED yellow with start2 marking for start input
Net weight 0.200 kg
Input terminal Power supply
Mounting support 35 mm symmetrical DIN rail
depth 120 mm
minimum output voltage 5 V for relay output
Power consumption in va 6.0 VA 48...240 V AC 50/60 Hz
Power consumption in w 2.0 W 48...240 V DC
Safety outputs 4 NO + 1 NC
Input compatibility Normally closed circuit conforming to ISO 14119
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
input protection type Internal, electronic
Synchronisation time between inputs Unlimited
Safety level Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Type of start Automatic/manual/monitored
Environment
ip degree of protection IP20 (terminals) conforming to EN/IEC 60529
IP40 (housing) conforming to EN/IEC 60529
IP54 (mounting area) conforming to EN/IEC 60529
Range of product Harmony Safety Automation
ambient air temperature for operation -25…55 °C
standards IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
relative humidity 5…95 % non-condensing